<LOGO>
FM Transmitter Measurement Report
Created: 2024-12-13 13-13-34
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
89.40 MHz 5/5, 74 dBuV ISKELMA
Pilot RDS Phase Difference
6.4 kHz 2.8 kHz -83 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
7 kHz 64 kHz 19000 0,0000
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
4,1 dBr 5,33 dBr 6,5 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"ISKELMA " 62AD 9 (Varied) 1 0 1 1 --:--
RT
-
AF EON
89.4, 92.5, 95.0, 100.1 MHz -
FM Scope Max at: 64 kHz MIN: 7 kHz % above 76 kHz: 0,0000 Acquired: 2024/12/13 13.12.31 Total samples: 19000 Equivalent time: 0:15:50 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 2000 4000 6000
FM Scope MAX: 6,5 dBr MIN: 4,1 dBr AVE: 5,33 dBr % above 12,2 dBr: 0,0 Last value: 5,7 dBr (2024/12/13 13.12.31) 12.58 13.00 13.02 13.04 13.06 13.08 13.10 13.12 0 50 100 Dev. MAX [kHz] 0 2 4 6 Pm [dBr]